当前位置: X-MOL首页全球导师 海外导师 › Buhlmann, Philippe (Phil)

研究领域

Analytical & Bioanalytical Chemistry/Environmental & Green Chemistry/Nanoscience & Materials Chemistry/Chemical Physics

Our group is interested in the use of molecular recognition for chemical sensing. On one hand, we develop chemical sensors for clinical and environmental applications. Our research focuses on new receptors that bind analytes of interest with high selectivity, novel strategies to obtain very low detection limits, and perfluoropolymers that permit long-term monitoring and eventually the implantation into the human body. On the other hand, we chemically modify metal and carbon nanotube tips, and use them in scanning tunneling microscopy for chemically selective imaging with molecular resolution.

近期论文

查看导师新发文章 (温馨提示:请注意重名现象,建议点开原文通过作者单位确认)

Toxicity of Silver Nanoparticles in the Environment: Natural Organic Matter Effects on Nanoparticle Stability and Dissolution, Gunsolus, I. L.; Mousavi, M. P. S.; Buhlmann, P., Haynes, C. L. submitted 11 August 2014. Toxicity of Silver Nanoparticles in the Environment: Ag+ Binding to Natural Organic Matter, Mousavi, M. P. S.; Gunsolus, I. L.; Pérez de Jesús, C. E.; Haynes, C. L.; Buhlmann, P. submitted 11 August 2014. In Situ Atomic Resolution Studies of the Electrode/Solution Interface By Electrochemical Scanning Tunneling Microscopy, Thorgaard, S. N.; Buhlmann, P. in press. Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact, Zou, X. U.; Zhen, X. V.; Cheong, J. H.; Bühlmann, P, Anal. Chem, 2014 86 (17), 8687-8692. Paper-Based Potentiometric Ion Sensing, Lan, W.; Zou, X. U.; Hamedi, M. M.; Hu, J.; Parolo, C.; Maxwell, E. J.; Bühlmann, P.; Whitesides, G. M., in press May 2014. Ion-Selective Electrodes with Colloid-Imprinted Mesoporous Carbon as Solid Contact, Hu, J.; Zou, X. U.; Stein, A.; Bühlmann, P., Anall Chem. 2014, 86, 7111-7118 Ionic Liquid Reference Electrodes With a Well-Controlled Co(II)/Co(III) Redox Buffer as Solid Contact, Zou, X. U.; Chen, L. D.; Lai, C.-Z.; Bühlmann, P., Electroanalysis, 2014, 26, pp 1-8 Paper-Based Reference Electrode and Potentiometric Ion Sensing, Wan, W.; Maxwell, E.; Parolo, C.; Bwambok, D.; Thuo, M.; Subramaniam, A.; Whitesides, G.; Zou, X.; Hu, J.; Buhlmann, P. WO1 patent application 0042697.00391, April 2014. Ion-selective electrodes and reference electrodes with a solid contact having mesoporous carbon, Hu, J.; Stein, A.; Buhlmann, P. , provisional US patent application 23 May 2014. Three Dimensionally Ordered Mesoporous (3DOm) Carbon Materialas Electrodes for Electrical Double-Layer Capacitors with Ionic Liquid Electrolytes, Anh Vu, Xiaoyue Li, John Phillips, Aijie Han, William H. Smyrl, Philippe Bühlmann, Andreas Stein Chem. Mater., Accepted, September 2013. Reference Electrodes with Salt Bridges Contained in Nanoporous Glass: An Underappreciated Source of Error, Maral P.S. Mousavi and Philippe Bühlmann, Anal. Chem. 2013, 85 (19), pp 8895–8901 Solid Contact Ion-Selective Electrodes With a Well- Controlled Co(II)/Co(III) Redox Buffer Layer;Xu U. Zou , Jia H. Cheong , Brandon James Taitt , and Philippe Bühlmann, Anal. Chem., 2013, 85 (19), pp 9350–9355. Fluorous Membrane Ion-Selective Electrodes for Perfluorinated Surfactants: Trace Level Detection and In-Situ Monitoring of Adsorption onto Sand; Chen, L. D.§ ; Lai, C.-Z.§ ; Granda, L. P. ; Fierke, M. ; Mandal, D.; Stein, A.; Gladysz, J. A.; Bühlmann, P., Anal. Chem,.2013, 85 (15), pp 7471–7477.(§These authors contributed equally to this work) Characterization of Silver Ion Dissolution from Silver Nanoparticles using Fluorous-phase Ion-selective Electrodes and Assessment of Resultant Toxicity to Shewanella oneidensis: Melisa A. Maurer-Jones, Maral P. S. Mousavi, Li D Chen, Philippe Buhlmann, Christy Haynes, Chem. Sci., 2013, 4, 2564-2572 Current Pulse Based Reference Electrodes Without Liquid Junctions; Zou, Xu; Buhlmann, Philippe, Anal. Chem., 2013, 85 (8), pp 3817–3821 Lifting of the (√3 x 22) Surface Reconstruction of Au(111) in Halide Solutions as a Sensitive Probe to Monitor Adsorption of Cyclodextrin and Its Complexes; Thorgaard, S. N.; Bühlmann, P., Journal of Electroanalytical Chemistry, 2013, 693, pp1-8 Quenching Performance of Surfactant-containing and Surfactant-free Fluorophore-doped Mesoporous Silica Films for Nitroaromatic Compound Detection, Anh Vu, John Phillips, Philippe Bühlmann, and Andreas Stein, Chemistry of Materials, 2013, 25 (5) pp 711-722. Unbiased Assessment of Electrochemical Windows: Minimizing Mass Transfer Effects on the Evaluation of Anodic and Cathodic Limits, Olson E. J. Bühlmann, P., Journal of the Electrochemical Society, 2013, 160 (2) ppA320-A323. A Highly Selective Cyanide-Selective Electrode Based on Zn(II) Tetraphenylporphyrin as Ionophore, Chen, L. D.;Zou, Xu U ;Bühlmann, P., Anal. Chem., 2012, 84 (21), pp 9192–9198 Receptor-Based Detection of 2,4-Dinitrotoluene using Modified Three-Dimensionally Ordered Macroporous Carbon Electrodes, Fierke, M.; Olson, E. J., Bühlmann, P.; Stein, A., ACS Appl. Mater. Interfaces, 2012, 4 (9), pp 4731–4739

推荐链接
down
wechat
bug