European Journal of Nuclear Medicine and Molecular Imaging ( IF 8.6 ) Pub Date : 2024-12-17 , DOI: 10.1007/s00259-024-07004-1 Peipei Wang, Chao Ren, Liang Wang, Hao Qian, Fang Li, Xinhui Su, Zhujun Shen, Bailing Hsu, Li Huo
Aims
This study aimed to evaluate image quality, myocardial perfusion, and diagnostic performance of a novel [18F]F-labeled PET tracer, XTR004 PET, myocardial perfusion imaging (MPI) compared with [13N]Ammonia (NH3) PET MPI.
Methods and results
Forty-seven patients with suspected or known coronary artery disease (CAD) were prospectively enrolled to undergo one-day rest/ATP-stress XTR004 and NH3 electrocardiograph-gated PET imaging within 2 weeks. Among them, twenty-six patients underwent invasive coronary angiography (ICA), and nineteen were identified with flow-limited CAD (stenosis ≥ 70%). Image quality (excellent/good/average) and certainty of interpretation were evaluated by two independent, blinded readers. Despite a higher liver uptake, XTR004 achieved good to excellent image quality in 83% of cases, comparable to 95.7% of NH3(P = 0.091). Additionally, the diagnostic certainty, measured as the percentage of cases with definitely abnormal or normal interpretations, was similar between XTR004 and NH3, with results of 87.2% and 89.2%, respectively. The sensitivity and specificity levels of XTR004 and NH3 MPI were similar (79% vs. 79%, 86% vs. 71%, P = 1.00). Linear regression of rest/stress myocardial perfusion in 17 segments revealed the linear slope close to unity with excellent R2 value (rest: slope = 0.954–1.074, R2 = 0.990–0.997; stress: slope = 0.951–1.082, R2 = 0.971–0.996). XTR004 was tolerated well by all patients. No adverse events were reported.
Conclusion
XTR004 PET MPI demonstrated promising image quality, diagnostic certainty and myocardial perfusion characteristics comparable to NH3 PET MPI. Future research should concentrate on the quantitative analysis of myocardial blood flow to explore the clinical implications of XTR004 PET MPI.
Graphical Abstract
中文翻译:
新型 [18F] F 标记 PET 示踪剂 XTR004 与 [13N] 氨在冠状动脉疾病心肌灌注成像中的比较评价
目标
本研究旨在评估新型 [18F]F 标记的 PET 示踪剂 XTR004 PET、心肌灌注成像 (MPI) 与 [13N] 氨 (NH3) PET MPI 相比的图像质量、心肌灌注和诊断性能。
方法和结果
前瞻性纳入 47 例疑似或已知冠状动脉疾病 (CAD) 患者,在 2 周内接受 1 天休息/ATP 应激 XTR004 和 NH3 心电图门控 PET 成像。其中 26 例患者接受了有创冠状动脉造影 (ICA),19 例被确定为血流受限型 CAD (狭窄≥ 70%)。图像质量 (优秀/良好/一般) 和解释质量由两名独立的盲法读者评估。尽管肝脏摄取较高,但 XTR004 在 83% 的病例中实现了良好至极好的图像质量,与 NH3 的 95.7% 相当 (P = 0.091)。此外,XTR004 和 NH3 之间的诊断质量(以明确异常或正常解释的病例百分比衡量)相似,结果分别为 87.2% 和 89.2%。XTR004 和 NH3 MPI 的敏感性和特异性水平相似 (79% vs. 79%,86% vs. 71%,P = 1.00)。17 个节段中静息/负荷心肌灌注的线性回归显示线性斜率接近统一,具有优异的 R2 值(静息:斜率 = 0.954–1.074,R2 = 0.990–0.997;应力:斜率 = 0.951–1.082,R2 = 0.971–0.996)。XTR004 所有患者均耐受良好。未报告不良事件。
结论
XTR004 PET MPI 表现出与 NH3 PET MPI 相当的良好图像质量、诊断确定性和心肌灌注特性。未来的研究应集中在心肌血流的定量分析上,以探索 XTR004 PET MPI 的临床意义。