当前位置:
X-MOL 学术
›
Ultrason. Sonochem.
›
论文详情
Our official English website, www.x-mol.net, welcomes your
feedback! (Note: you will need to create a separate account there.)
Dual-frequency countercurrent ultrasonic-assisted extraction of the cold brew coffee and in situ real-time monitoring of extraction process
Ultrasonics Sonochemistry ( IF 8.7 ) Pub Date : 2024-10-20 , DOI: 10.1016/j.ultsonch.2024.107118 Huimin Liu, Dandan Liu, Wuli Wang, Xinyan Zhang, Jamila Tuly, Hanhan Li, Haile Ma
Ultrasonics Sonochemistry ( IF 8.7 ) Pub Date : 2024-10-20 , DOI: 10.1016/j.ultsonch.2024.107118 Huimin Liu, Dandan Liu, Wuli Wang, Xinyan Zhang, Jamila Tuly, Hanhan Li, Haile Ma
This research aimed to examine the effect of countercurrent ultrasound on extraction efficiency of cold brew coffee (CBC). The quality and flavor of CBC obtained by ultrasonic-assisted extraction (UE) were evaluated and compared with traditional extraction (TE). Meanwhile, the UE process was monitored in situ real-time using a near-infrared (NIR) spectrometer. The optimal UE parameters obtained by experiments were dual-frequency of 20/28 kHz, countercurrent ultrasonic treatment time of 50 min, ultrasonic power density of 320 W/L, and material-liquid ratio of 1:15. Under the optimal parameters, the total dissolved solids content (TDS) and extraction yield (EY) were 1.63 % and 20.52 %, respectively. This resulted in an 83.33 % improvement in efficiency matching the TDS and EY of a 5-h TE CBC. In comparison with the control, the contents of total polyphenols, total sugars, and total lipids after ultrasonic treatment increased by 13.79 %, 28.49 %, and 333.33 %, respectively, while the total acids content decreased by 27.81 %. HPLC and HS-SPME-GC/MS analysis showed similar non-volatile and volatile flavor components between UE and TE CBC. A quantitative partial least squares (PLS) prediction model was developed to monitor TDS and CGA levels during the UE CBC. This model demonstrated excellent calibration and prediction performance. (TDS: Rc = 0.9281; RMSECV = 0.0694; Rp = 0.9514; RMSEP = 0.0631. CGA: Rc = 0.9086; RMSECV = 0.0316; Rp = 0.9467; RMSEP = 0.0212). This study explored an efficient approach for the industrialization of CBC production and provided theoretical support for developing an intelligent control system for its process.
中文翻译:
双频逆流超声波辅助萃取冷萃咖啡,并现场实时监测萃取过程
本研究旨在检验逆流超声对冷萃咖啡 (CBC) 提取效率的影响。评价超声辅助萃取 (UE) 获得的 CBC 的品质和风味,并与传统萃取 (TE) 进行比较。同时,使用近红外 (NIR) 光谱仪对 UE 过程进行原位实时监测。实验得到的最佳UE参数为双频20/28 kHz,逆流超声处理时间50 min,超声功率密度320 W/L,料液比1:15。在最佳参数下,总溶解固体含量 (TDS) 和提取率 (EY) 分别为 1.63 % 和 20.52 %。这导致与 5 小时 TE CBC 的 TDS 和 EY 相匹配的效率提高了 83.33%。与对照相比,超声处理后总多酚、总糖和总脂质含量分别增加了 13.79 %、28.49 % 和 333.33 %,而总酸含量降低了 27.81 %。HPLC 和 HS-SPME-GC/MS 分析显示 UE 和 TE CBC 之间的非挥发性和挥发性风味成分相似。开发了一个定量偏最小二乘法 (PLS) 预测模型来监测 UE CBC 期间的 TDS 和 CGA 水平。该模型表现出出色的校准和预测性能。(TDS:Rc = 0.9281;RMSECV = 0.0694;Rp = 0.9514;RMSEP = 0.0631。CGA:Rc = 0.9086;RMSECV = 0.0316;Rp = 0.9467;RMSEP = 0.0212)。本研究探索了一种高效的 CBC 生产工业化方法,为开发 CBC 过程智能控制系统提供了理论支持。
更新日期:2024-10-20
中文翻译:
双频逆流超声波辅助萃取冷萃咖啡,并现场实时监测萃取过程
本研究旨在检验逆流超声对冷萃咖啡 (CBC) 提取效率的影响。评价超声辅助萃取 (UE) 获得的 CBC 的品质和风味,并与传统萃取 (TE) 进行比较。同时,使用近红外 (NIR) 光谱仪对 UE 过程进行原位实时监测。实验得到的最佳UE参数为双频20/28 kHz,逆流超声处理时间50 min,超声功率密度320 W/L,料液比1:15。在最佳参数下,总溶解固体含量 (TDS) 和提取率 (EY) 分别为 1.63 % 和 20.52 %。这导致与 5 小时 TE CBC 的 TDS 和 EY 相匹配的效率提高了 83.33%。与对照相比,超声处理后总多酚、总糖和总脂质含量分别增加了 13.79 %、28.49 % 和 333.33 %,而总酸含量降低了 27.81 %。HPLC 和 HS-SPME-GC/MS 分析显示 UE 和 TE CBC 之间的非挥发性和挥发性风味成分相似。开发了一个定量偏最小二乘法 (PLS) 预测模型来监测 UE CBC 期间的 TDS 和 CGA 水平。该模型表现出出色的校准和预测性能。(TDS:Rc = 0.9281;RMSECV = 0.0694;Rp = 0.9514;RMSEP = 0.0631。CGA:Rc = 0.9086;RMSECV = 0.0316;Rp = 0.9467;RMSEP = 0.0212)。本研究探索了一种高效的 CBC 生产工业化方法,为开发 CBC 过程智能控制系统提供了理论支持。