Successful trans-femoral retrieval of a stuck axillary Impella 5.0 device
Journal of Artificial Organs ( IF 1.1 ) Pub Date : 2022-11-27 , DOI: 10.1007/s10047-022-01373-w
Yusuke Hamada 1 , Kazuo Shimamura 1 , Keiwa Kin 1 , Takuji Kawamura 1 , Noriyuki Kashiyama 1 , Koichi Toda 1 , Yoshiki Sawa 1 , Shigeru Miyagawa 1
中文翻译:
成功经股骨取出卡住的腋窝 Impella 5.0 装置
更新日期:2022-11-27
Journal of Artificial Organs ( IF 1.1 ) Pub Date : 2022-11-27 , DOI: 10.1007/s10047-022-01373-w
Yusuke Hamada 1 , Kazuo Shimamura 1 , Keiwa Kin 1 , Takuji Kawamura 1 , Noriyuki Kashiyama 1 , Koichi Toda 1 , Yoshiki Sawa 1 , Shigeru Miyagawa 1
Affiliation
![]() |
We describe a case in which an axillary Impella 5.0, stuck in an area of calcification in the right subclavian artery, could not be retrieved in the usual manner. However, it was successfully removed using a long 22-Fr sheath and snaring catheter by means of the trans-femoral artery. Device retrieval using the trans-femoral artery snare technique is considered a valid option for removing the Impella device in patients who exhibit this complication.
中文翻译:

成功经股骨取出卡住的腋窝 Impella 5.0 装置
我们描述了一个病例,其中腋窝 Impella 5.0 卡在右锁骨下动脉的钙化区域,无法以通常的方式取出。然而,使用长 22-Fr 护套和圈套导管通过股动脉将其成功取出。对于出现这种并发症的患者,使用经股动脉圈套器技术取出装置被认为是移除 Impella 装置的有效选择。