Our official English website, www.x-mol.net, welcomes your
feedback! (Note: you will need to create a separate account there.)
Evaluation of the effects of differences in silicone hardness on rat model of lumbar spinal stenosis.
PLOS ONE ( IF 2.9 ) Pub Date : 2021-05-13 , DOI: 10.1371/journal.pone.0251464 Hyunseong Kim 1 , Jin Young Hong 1 , Wan-Jin Jeon 1 , Junseon Lee 1 , In-Hyuk Ha 1
PLOS ONE ( IF 2.9 ) Pub Date : 2021-05-13 , DOI: 10.1371/journal.pone.0251464 Hyunseong Kim 1 , Jin Young Hong 1 , Wan-Jin Jeon 1 , Junseon Lee 1 , In-Hyuk Ha 1
Affiliation
Lumbar spinal stenosis (LSS), one of the most commonly reported spinal disorders, can cause loss of sensation and dyskinesia. In currently used animal models of LSS, the spinal cord is covered entirely with a silicone sheet, or block-shaped silicone is inserted directly into the spinal canal after laminectomy. However, the effects of differences between these implant materials have not been studied. We assessed the degree of damage and locomotor function of an LSS model in Sprague-Dawley rats using silicone blocks of varying hardness (70, 80, and 90 kPa) implanted at the L4 level. In sham rats, the spinal cord remained intact; in LSS rats, the spinal cord was increasingly compressed by the mechanical pressure of the silicone blocks as hardness increased. Inflammatory cells were not evident in sham rats, but numerous inflammatory cells were observed around the implanted silicone block in LSS rats. CD68+ cell quantification revealed increases in the inflammatory response in a hardness-dependent manner in LSS rats. Compared with those in sham rats, proinflammatory cytokine levels were significantly elevated in a hardness-dependent manner, and locomotor function was significantly decreased, in LSS rats. Overall, this study showed that hardness could be used as an index to control the severity of nerve injury induced by silicone implants.
中文翻译:
硅胶硬度差异对大鼠腰椎管狭窄模型的影响评价。
腰椎管狭窄症 (LSS) 是最常见的脊柱疾病之一,可导致感觉丧失和运动障碍。在目前使用的LSS动物模型中,脊髓完全被硅胶片覆盖,或者在椎板切除术后将块状硅胶直接插入椎管内。然而,尚未研究这些植入材料之间差异的影响。我们使用植入 L4 水平的不同硬度(70、80 和 90 kPa)的硅胶块评估了 Sprague-Dawley 大鼠 LSS 模型的损伤程度和运动功能。在假手术大鼠中,脊髓保持完整;在 LSS 大鼠中,随着硬度的增加,硅胶块的机械压力越来越多地压缩脊髓。在假手术大鼠中炎症细胞不明显,但在 LSS 大鼠中植入的硅胶块周围观察到大量炎症细胞。 CD68+细胞定量显示LSS大鼠的炎症反应以硬度依赖性方式增加。与假手术大鼠相比,LSS 大鼠的促炎细胞因子水平以硬度依赖性方式显着升高,并且运动功能显着下降。总的来说,这项研究表明硬度可以作为控制硅胶植入物引起的神经损伤严重程度的指标。
更新日期:2021-05-13
中文翻译:
硅胶硬度差异对大鼠腰椎管狭窄模型的影响评价。
腰椎管狭窄症 (LSS) 是最常见的脊柱疾病之一,可导致感觉丧失和运动障碍。在目前使用的LSS动物模型中,脊髓完全被硅胶片覆盖,或者在椎板切除术后将块状硅胶直接插入椎管内。然而,尚未研究这些植入材料之间差异的影响。我们使用植入 L4 水平的不同硬度(70、80 和 90 kPa)的硅胶块评估了 Sprague-Dawley 大鼠 LSS 模型的损伤程度和运动功能。在假手术大鼠中,脊髓保持完整;在 LSS 大鼠中,随着硬度的增加,硅胶块的机械压力越来越多地压缩脊髓。在假手术大鼠中炎症细胞不明显,但在 LSS 大鼠中植入的硅胶块周围观察到大量炎症细胞。 CD68+细胞定量显示LSS大鼠的炎症反应以硬度依赖性方式增加。与假手术大鼠相比,LSS 大鼠的促炎细胞因子水平以硬度依赖性方式显着升高,并且运动功能显着下降。总的来说,这项研究表明硬度可以作为控制硅胶植入物引起的神经损伤严重程度的指标。