目的:本研究旨在表征PASCAL系统的实际性能和临床结果,PASCAL系统是一种用于经导管二尖瓣修复的小叶近似装置。
方法和结果:尽管有最佳药物治疗,但仍有50例NYHA II-IV级患者(中位年龄78.0岁[IQR 74.5-81.0],女性52%,对数EuroSCORE 21.6 [IQR 13.2-30.2])接受了严重二尖瓣关闭不全(MR)的治疗,并进行了随访一个月。分别有24%和68%的患者存在原发性和继发性MR,而混合病因则占8%。在26/50的患者中采用1装置策略(52%),在23/50的患者中采用2装置策略(46%),在1/50的患者中采用3装置策略(2%)。分别在100%和98%的患者中获得了技术和程序上的成功。出院时39/50(78%)的患者观察到MR≤1,一个月时36/46(78%)的患者观察到MRV梯度在所有患者中均保持≤5 mmHg。在随访期间观察到一种装置栓塞和一种单瓣装置附件。
结论:在现实世界中,PASCAL设备可有效降低MR并改善短期随访的功能。
视觉摘要。二尖瓣反流的PASCAL系统。